7SFX
10A1 Fab in complex with CD99 peptide
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2021-06-30 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.979 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 65.410, 131.550, 119.811 |
Unit cell angles | 90.00, 90.12, 90.00 |
Refinement procedure
Resolution | 46.380 - 3.100 |
R-factor | 0.2318 |
Rwork | 0.226 |
R-free | 0.24770 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2xza |
RMSD bond length | 0.006 |
RMSD bond angle | 1.055 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX (1.19.2_4158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 3.150 |
High resolution limit [Å] | 3.100 | 3.100 |
Rmeas | 0.157 | 0.456 |
Rpim | 0.069 | 0.198 |
Number of reflections | 36430 | 1834 |
<I/σ(I)> | 10.97 | 4.35 |
Completeness [%] | 98.9 | 99.3 |
Redundancy | 5.1 | 5.2 |
CC(1/2) | 0.991 | 0.868 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291.15 | 0.2 M lithium sulfate monohydrate, 0.1 M HEPES, pH 7.3, 25% PEG3350, and 0.1 M L-Proline |