7S4G
Fab fragment bound to the Cter peptide of Ly6G6D
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRL BEAMLINE BL12-2 |
Synchrotron site | SSRL |
Beamline | BL12-2 |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2018-05-23 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 1 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 69.286, 133.389, 100.038 |
Unit cell angles | 90.00, 90.03, 90.00 |
Refinement procedure
Resolution | 35.050 - 2.200 |
R-factor | 0.194 |
Rwork | 0.192 |
R-free | 0.23480 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1fve |
RMSD bond length | 0.012 |
RMSD bond angle | 1.171 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.18.2_3874) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.820 | 2.240 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.159 | 1.109 |
Number of reflections | 90064 | 8758 |
<I/σ(I)> | 10.2 | |
Completeness [%] | 97.7 | |
Redundancy | 7.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 292 | 0.1M HEPES pH 7, 15% PEG4000 |