Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7R6H

RHCC in complex with o-carborane

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2020-10-28
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.5418
Spacegroup nameP 21 21 21
Unit cell lengths34.450, 55.920, 110.230
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution18.690 - 2.200
R-factor0.2253
Rwork0.222
R-free0.26620
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1ybk
RMSD bond length0.003
RMSD bond angle0.389
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.19.2-4158_4158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]18.6902.270
High resolution limit [Å]2.2002.200
Rmerge0.0690.171
Rmeas0.0840.208
Number of reflections222245798
<I/σ(I)>14.28
Completeness [%]98.999.5
Redundancy5.45.6
CC(1/2)0.9980.991
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.52930.1 M ammonium acetate, 0.05 M sodium cacodylate trihydrate, 10% v/v 2-propanol, 0.015 M magnesium acetate tetrahydrate

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon