7QFF
Peptide VACKSSQP in complex with human cathepsin V C25A mutant
This is a non-PDB format compatible entry.
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | ELETTRA BEAMLINE 11.2C |
| Synchrotron site | ELETTRA |
| Beamline | 11.2C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-09-26 |
| Detector | DECTRIS PILATUS 6M |
| Wavelength(s) | 1 |
| Spacegroup name | P 43 21 2 |
| Unit cell lengths | 94.400, 94.400, 126.830 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 47.200 - 1.500 |
| R-factor | 0.1691 |
| Rwork | 0.169 |
| R-free | 0.19440 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 1fh0 |
| Data reduction software | XDS |
| Data scaling software | XDS |
| Phasing software | MOLREP |
| Refinement software | MAIN |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.554 |
| High resolution limit [Å] | 1.500 | 1.500 |
| Number of reflections | 91924 | 8990 |
| <I/σ(I)> | 32.9 | |
| Completeness [%] | 99.9 | |
| Redundancy | 13.8 | |
| CC(1/2) | 1.000 | 0.768 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 277 | 77 % MPD, 23 % of 60 mM TRIS, pH 8 |