Loading
PDBj
MenuPDBj@FacebookPDBj@X(formerly Twitter)PDBj@BlueSkyPDBj@YouTubewwPDB FoundationwwPDBDonate
RCSB PDBPDBeBMRBAdv. SearchSearch help

7PED

DEPTOR DEP domain tandem (DEPt)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2016-11-19
DetectorDECTRIS EIGER X 16M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths50.862, 99.014, 68.245
Unit cell angles90.00, 109.68, 90.00
Refinement procedure
Resolution53.903 - 1.930
R-factor0.2113
Rwork0.211
R-free0.22620
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4f7z
Data reduction softwareDIALS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]99.0101.980
High resolution limit [Å]1.9301.930
Rmerge0.0331.132
Number of reflections465942829
<I/σ(I)>14.2
Completeness [%]97.4
Redundancy4.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP277.15PEG3350,natrium hydrochlorid

229380

PDB entries from 2024-12-25

PDB statisticsPDBj update infoContact PDBjnumon