Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7O52

CD22 d6-d7 in complex with Fab m971

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyPIXEL
Collection date2017-08-26
DetectorDECTRIS PILATUS3 6M
Wavelength(s)1.033200
Spacegroup nameI 2 2 2
Unit cell lengths61.478, 119.719, 241.672
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.823 - 2.410
Rwork0.226
R-free0.26400
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)7o4y
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (v1.14)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.0007.5312.550
High resolution limit [Å]2.4107.1502.410
Rmerge0.0980.0341.681
Rmeas0.1020.0351.751
Number of reflections3503114695468
<I/σ(I)>20.1966.811.46
Completeness [%]99.699.397.4
Redundancy13.1811.79812.624
CC(1/2)0.9990.9990.584
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2932M ammonium sulphate, 0.1M HEPES pH 7.5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon