Experimental procedure
| Detector technology | IMAGE PLATE |
| Detector | RIGAKU RAXIS |
| Wavelength(s) | 1.5418 |
| Spacegroup name | I 4 3 2 |
| Unit cell lengths | 182.800, 182.800, 182.800 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 6.000 - 2.000 |
| R-factor | 0.152 |
| Rwork | 0.152 |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.790 |
| Data reduction software | R-AXIS |
| Phasing software | X-PLOR |
| Refinement software | X-PLOR |
Data quality characteristics
| Overall | Outer shell | |
| High resolution limit [Å] | 2.000 * | 2.000 * |
| Rmerge | 0.012 | 0.175 * |
| Number of reflections | 33570 | |
| Completeness [%] | 66.0 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | Vapor diffusion * | 6.6 * |
Crystallization Reagents in Literatures
| ID | crystal ID | solution | reagent name | concentration (unit) | details |
| 1 | 1 | drop | protein | 10-15 (mg/ml) | |
| 2 | 1 | drop | potassium phosphate | 1.7 (M) | |
| 3 | 1 | reservoir | potassium phosphate | 1.9 (M) |