P70 S6K1 IN COMPLEX WITH MSC2317067A-1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2010-03-25
DetectorDECTRIS PILATUS 2M
Wavelength(s)1
Spacegroup nameP 21 21 21
Unit cell lengths59.300, 74.550, 150.030
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.520 - 3.000
Rwork0.212
R-free0.27180
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)3a60
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareCNX
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.5203.170
High resolution limit [Å]3.0003.000
Rmerge0.1480.522
Rmeas0.1680.564
Number of reflections138832106
<I/σ(I)>11.52.86
Completeness [%]96.195.8
Redundancy5.875.49
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.52950.2M Bis-Tris pH 5.5, 0.1M Li2SO4, 26-28% PEG3350