7MA9
HIV-1 Protease (I84V) in Complex with UMass9
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2017-03-11 |
| Detector | RIGAKU SATURN 944 |
| Wavelength(s) | 1.54178 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 51.099, 57.781, 62.308 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 21.879 - 1.900 |
| R-factor | 0.1812 |
| Rwork | 0.180 |
| R-free | 0.20630 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6dgx |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.741 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.12_2829) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 21.900 | 1.930 |
| High resolution limit [Å] | 1.900 | 1.900 |
| Rmerge | 0.063 | 0.340 |
| Number of reflections | 14694 | 1411 |
| <I/σ(I)> | 30.2 | 4.8 |
| Completeness [%] | 97.2 | 90.5 |
| Redundancy | 7.1 | 6 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 23-24% (w/v) Ammonium Sulfate, 0.1M Bis-Tris-Methane-HCl Buffer pH 5.5 |