7MA7
HIV-1 Protease (I84V) in Complex with UMass7
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | ROTATING ANODE |
| Source details | RIGAKU MICROMAX-007 HF |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2017-02-13 |
| Detector | RIGAKU SATURN 944 |
| Wavelength(s) | 1.54178 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 50.971, 57.715, 62.258 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 21.833 - 1.919 |
| R-factor | 0.1636 |
| Rwork | 0.162 |
| R-free | 0.20010 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6dgx |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.713 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.12_2829) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 21.840 | 1.940 |
| High resolution limit [Å] | 1.910 | 1.910 |
| Rmerge | 0.051 | 0.195 |
| Number of reflections | 13180 | 1265 |
| <I/σ(I)> | 27.3 | 6.9 |
| Completeness [%] | 90.2 | 86 |
| Redundancy | 4.6 | 4.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 23-24% (w/v) Ammonium Sulfate, 0.1M Bis-Tris-Methane-HCl Buffer pH 5.5 |