Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7M0K

HPK1 IN COMPLEX WITH COMPOUND 1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2019-06-17
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.00000
Spacegroup nameP 1
Unit cell lengths45.074, 76.627, 89.200
Unit cell angles90.02, 97.02, 89.98
Refinement procedure
Resolution88.530 - 2.010
R-factor0.2483
Rwork0.248
R-free0.27800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)previously solved structure
RMSD bond length0.011
RMSD bond angle1.470
Data scaling softwareXSCALE
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]88.5302.260
High resolution limit [Å]2.0102.010
Rmeas0.0450.590
Number of reflections7474221707
<I/σ(I)>12.372.15
Completeness [%]94.792.6
Redundancy2.22.2
CC(1/2)0.9990.998
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION2937% PEG 5K MNE, 0.05 M HEPES pH 6.5, Na3Cit pH 7, 20 mM Tris pH 8.0 , 150 mM NaCl , 5% Glycerol

219869

PDB entries from 2024-05-15