7LYU

Reelin repeat 8

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX1
Synchrotron siteAustralian Synchrotron
BeamlineMX1
Temperature [K]100
Detector technologyPIXEL
Collection date2020-09-30
DetectorDECTRIS EIGER2 X 9M
Wavelength(s)0.953724
Spacegroup nameP 1 21 1
Unit cell lengths60.171, 104.059, 67.615
Unit cell angles90.00, 104.11, 90.00
Refinement procedure
Resolution45.120 - 3.000
R-factor0.229
Rwork0.227
R-free0.26350
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2e26
RMSD bond length0.005
RMSD bond angle0.895
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwareMrBUMP
Refinement softwarePHENIX (1.19.1_4122)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.1203.180
High resolution limit [Å]3.0003.000
Number of reflections162632620
<I/σ(I)>5.51.3
Completeness [%]99.9
Redundancy3.6
CC(1/2)0.9850.496
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP82930.1M Tris pH 8, 35% PEG 1000

219869