7JX0
NVS-PI3-4 bound to the PI3Kg catalytic subunit p110 gamma
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2020-08-24 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.9795 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 143.620, 67.560, 106.830 |
Unit cell angles | 90.00, 95.41, 90.00 |
Refinement procedure
Resolution | 44.736 - 3.150 |
R-factor | 0.2309 |
Rwork | 0.229 |
R-free | 0.27220 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 5jha |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.16_3549) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 44.736 | 3.260 |
High resolution limit [Å] | 3.150 | 3.150 |
Rmerge | 0.119 | 1.118 |
Number of reflections | 17573 | 1761 |
<I/σ(I)> | 7.92 | 0.84 |
Completeness [%] | 98.1 | 99.04 |
Redundancy | 3 | |
CC(1/2) | 0.994 | 0.425 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 298 | 100 mM Tris pH 7.5, 250 mM (NH4)2SO4 and 20-22% PEG 4000 |