7JTQ
Human Complement Factor B Inhibited by a Slow Off-Rate Modified Aptamer of 31 Bases
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-11-26 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.97243 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 87.044, 145.751, 87.064 |
Unit cell angles | 90.00, 109.62, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 3.630 |
High resolution limit [Å] | 3.500 | 7.530 | 3.500 |
Rmerge | 0.237 | 0.133 | 0.697 |
Rmeas | 0.281 | 0.154 | 0.841 |
Rpim | 0.147 | 0.074 | 0.461 |
Total number of observations | 84318 | ||
Number of reflections | 24998 | 2602 | 2428 |
<I/σ(I)> | 3.6 | ||
Completeness [%] | 97.3 | 98.6 | 93.6 |
Redundancy | 3.4 | 3.6 | 3 |
CC(1/2) | 0.959 | 0.590 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.1 M HEPES (pH 7.5), 0.2 M ammonium acetate, 25% (w/v) peg-3350 |