Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7F7O

APC-Asef FP assay tracer

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL19U1
Synchrotron siteSSRF
BeamlineBL19U1
Temperature [K]93
Detector technologyPIXEL
Collection date2020-11-19
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.978
Spacegroup nameP 21 21 21
Unit cell lengths57.234, 71.619, 83.873
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution54.460 - 2.800
R-factor0.2872
Rwork0.285
R-free0.32800
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5iz6
RMSD bond length0.007
RMSD bond angle0.951
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0135)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]54.4602.850
High resolution limit [Å]2.8002.800
Rmerge0.649
Number of reflections889051835
<I/σ(I)>3.4
Completeness [%]99.4
Redundancy5.8
CC(1/2)0.9900.920
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2910.2M Ammonium sulfate, 0.1M Tris pH 8.0, 25% w/v PEG 3350

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon