7CQL

Apo GmaS without ligand

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRF BEAMLINE BL18U1
Synchrotron siteSSRF
BeamlineBL18U1
Temperature [K]100
Detector technologyPIXEL
Collection date2019-01-05
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.979
Spacegroup nameI 2 2 2
Unit cell lengths115.909, 179.024, 192.231
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution40.573 - 2.801
R-factor0.203
Rwork0.200
R-free0.25130
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4lni
RMSD bond length0.009
RMSD bond angle1.216
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.6.4_486)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.900
High resolution limit [Å]2.8006.0342.800
Rmerge0.1280.0730.310
Rmeas0.1340.0770.325
Rpim0.0400.0220.099
Total number of observations545098
Number of reflections4833150644782
<I/σ(I)>15.4
Completeness [%]98.698.899.1
Redundancy11.312.110.7
CC(1/2)0.9980.985
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP6.52910.1 M MES (pH 6.5), 1 M lithium sulfate

219869