7BY5
Tetanus neurotoxin mutant-(H233A/E234Q/H237A/Y375F)
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SPRING-8 BEAMLINE BL44XU |
| Synchrotron site | SPring-8 |
| Beamline | BL44XU |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2020-01-24 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.987 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 145.542, 145.542, 129.038 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 48.280 | 2.320 |
| High resolution limit [Å] | 2.270 | 2.270 |
| Rmerge | 0.126 | 1.030 |
| Rmeas | 0.137 | |
| Rpim | 0.053 | 0.446 |
| Number of reflections | 72360 | 4203 |
| <I/σ(I)> | 10.7 | 1.7 |
| Completeness [%] | 99.2 | 94.7 |
| Redundancy | 6.6 | 5.9 |
| CC(1/2) | 0.997 | 0.634 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7 | 293 | 0.1 M MOPS pH 7.0, 9% PEG 8000 |