Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I24 |
Synchrotron site | Diamond |
Beamline | I24 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-12-08 |
Detector | DECTRIS EIGER2 XE 16M |
Wavelength(s) | 0.9795 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 73.045, 114.914, 116.866 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.629 - 2.200 |
Rwork | 0.202 |
R-free | 0.22990 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | GDAP1 |
RMSD bond length | 0.014 |
RMSD bond angle | 1.790 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0267) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.630 | 2.279 |
High resolution limit [Å] | 2.200 | 2.200 |
Number of reflections | 50525 | 4965 |
<I/σ(I)> | 12.72 | |
Completeness [%] | 99.7 | |
Redundancy | 6.6 | |
CC(1/2) | 0.998 | 0.657 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.2 M Lithium sulfate, 0.1 M bis-Tris pH 5.5, 25% w/v PEG 3350 |