Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

7A8A

rsGreen0.7-K206A-F145Q partially in the green-off state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 2
Synchrotron siteSOLEIL
BeamlinePROXIMA 2
Temperature [K]100
Detector technologyPIXEL
Collection date2017-06-28
DetectorDECTRIS EIGER X 9M
Wavelength(s)0.9801
Spacegroup nameH 3 2
Unit cell lengths140.760, 140.760, 73.264
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution46.856 - 1.930
R-factor0.2062
Rwork0.204
R-free0.25380
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.007
RMSD bond angle0.909
Data reduction softwareXDS
Data scaling softwareAimless (0.5.32)
Phasing softwarePHASER (2.7.16)
Refinement softwarePHENIX (1.11)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]46.86046.8601.980
High resolution limit [Å]1.9309.0501.930
Rmerge0.0520.0350.670
Rmeas0.0530.0360.690
Rpim0.0120.0090.162
Total number of observations419528374325718
Number of reflections209702301407
<I/σ(I)>34.182.35
Completeness [%]100.099.3100
Redundancy2016.318.3
CC(1/2)1.0000.9980.971
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP293200 mM NaCl 100 mM MES pH 6.0 20 % PEG 6000

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon