7A86
rsGreen0.7-K206A-F145L partially in the green-off state
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 2 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-06-28 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.9801 |
Spacegroup name | P 1 |
Unit cell lengths | 48.102, 58.290, 58.466 |
Unit cell angles | 64.06, 71.06, 72.61 |
Refinement procedure
Resolution | 44.717 - 1.900 |
R-factor | 0.1826 |
Rwork | 0.181 |
R-free | 0.21050 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.007 |
RMSD bond angle | 0.913 |
Data reduction software | XDS |
Data scaling software | Aimless (0.5.32) |
Phasing software | PHASER (2.7.16) |
Refinement software | PHENIX (1.11.1_2575) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 44.720 | 44.720 | 1.940 |
High resolution limit [Å] | 1.900 | 9.110 | 1.900 |
Rmerge | 0.035 | 0.019 | 0.490 |
Rmeas | 0.042 | 0.023 | 0.575 |
Rpim | 0.022 | 0.012 | 0.298 |
Total number of observations | 140799 | 1254 | 9580 |
Number of reflections | 40412 | 371 | 2624 |
<I/σ(I)> | 14.8 | 44.1 | 2.5 |
Completeness [%] | 96.6 | 96.4 | 96.2 |
Redundancy | 3.5 | 3.4 | 3.7 |
CC(1/2) | 0.999 | 0.999 | 0.903 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 100 mM MES pH 6.5 12 % PEG 20 000 4 % Pentaerythritol ethoxylate |