Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-06-11 |
Detector | PSI PILATUS 6M |
Wavelength(s) | 1 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 153.421, 123.171, 73.126 |
Unit cell angles | 90.00, 107.90, 90.00 |
Refinement procedure
Resolution | 47.070 - 2.930 |
R-factor | 0.2468 |
Rwork | 0.244 |
R-free | 0.29010 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3q0x |
RMSD bond length | 0.005 |
RMSD bond angle | 0.902 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.15_3459) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.080 | 3.110 |
High resolution limit [Å] | 2.930 | 2.930 |
Rmeas | 0.011 | |
Number of reflections | 53262 | 8421 |
<I/σ(I)> | 9.15 | |
Completeness [%] | 97.5 | |
Redundancy | 2.1 | |
CC(1/2) | 0.410 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 291 | 15% PEG 4000, 0.8M sodium formate, 0.1 M Tris pH 8.5 |