Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-E+ SUPERBRIGHT |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2016-10-25 |
Detector | RIGAKU SATURN A200 |
Wavelength(s) | 1.54178 |
Spacegroup name | P 21 21 2 |
Unit cell lengths | 71.877, 52.473, 32.070 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 42.380 - 1.550 |
Rwork | 0.165 |
R-free | 0.19470 |
Structure solution method | FOURIER SYNTHESIS |
Starting model (for MR) | in house model |
RMSD bond length | 0.003 |
RMSD bond angle | 1.163 |
Data reduction software | XDS |
Data scaling software | Aimless |
Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 42.380 | 1.640 |
High resolution limit [Å] | 1.550 | 1.550 |
Rmerge | 0.024 | 0.186 |
Number of reflections | 16200 | 1479 |
<I/σ(I)> | 31.6 | 4.7 |
Completeness [%] | 89.2 | 52.5 |
Redundancy | 3.4 | 2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | 30% PEG 300, 0.1M MES buffer pH6.5 |