6Z7Y
Human insulin in complex with the analytical antibody OXI-005 Fab
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X10SA |
Synchrotron site | SLS |
Beamline | X10SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-09-09 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 1.00 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 110.390, 173.230, 83.800 |
Unit cell angles | 90.00, 135.83, 90.00 |
Refinement procedure
Resolution | 48.420 - 2.200 |
R-factor | 0.2182 |
Rwork | 0.217 |
R-free | 0.25260 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6z7x |
RMSD bond length | 0.009 |
RMSD bond angle | 1.273 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (dev_3714) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.420 | 2.279 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.092 | 0.858 |
Rmeas | 0.110 | 1.016 |
Rpim | 0.059 | 0.540 |
Number of reflections | 54923 | 19188 |
<I/σ(I)> | 8.88 | 1.37 |
Completeness [%] | 99.0 | 99.59 |
Redundancy | 3.4 | 3.5 |
CC(1/2) | 0.993 | 0.549 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8 | 293 | 0.2 M magnesium chloride, 0.1 M Tris, pH 8, 20 % (w/v) PEG 6000 |