6Z5W
The RSL - sulfonato-calix[8]arene complex, P213 form, MES pH 6.8
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 2 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-09-21 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 0.98 |
Spacegroup name | P 21 3 |
Unit cell lengths | 63.826, 63.826, 63.826 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.132 - 1.187 |
R-factor | 0.1672 |
Rwork | 0.167 |
R-free | 0.17700 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2bt9 |
RMSD bond length | 0.006 |
RMSD bond angle | 0.892 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 45.132 | 1.207 |
High resolution limit [Å] | 1.187 | 1.187 |
Rmerge | 0.126 | 1.427 |
Rpim | 0.021 | 0.328 |
Number of reflections | 28303 | 1395 |
<I/σ(I)> | 19 | 2.3 |
Completeness [%] | 100.0 | 100 |
Redundancy | 36.8 | 19.7 |
CC(1/2) | 0.998 | 0.794 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293.15 | 0.1 M MES pH 6.8, 2.4 M Ammonium sulfate, 0.04 M sulfonato-calix[8]arene |