Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I24 |
| Synchrotron site | Diamond |
| Beamline | I24 |
| Temperature [K] | 80 |
| Detector technology | PIXEL |
| Collection date | 2019-02-23 |
| Detector | DECTRIS PILATUS3 6M |
| Wavelength(s) | 0.9686 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 48.110, 54.970, 282.430 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 47.470 - 1.740 |
| Rwork | 0.182 |
| R-free | 0.22260 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6z3b |
| RMSD bond length | 0.010 |
| RMSD bond angle | 1.517 |
| Data reduction software | Aimless |
| Data scaling software | XSCALE |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0258) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 47.470 | 1.770 |
| High resolution limit [Å] | 1.740 | 1.740 |
| Number of reflections | 93221 | 663 |
| <I/σ(I)> | 5.6 | |
| Completeness [%] | 100.0 | |
| Redundancy | 6.3 | |
| CC(1/2) | 1.000 | 0.700 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 293 | PEG3000, sodium citrate, |