Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6YLQ

EGFP in neutral pH, Directionality of Optical Properties of Fluorescent Proteins

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyPIXEL
Collection date2019-07-12
DetectorDECTRIS PILATUS 300K
Wavelength(s)1.54187
Spacegroup nameP 21 21 21
Unit cell lengths50.940, 62.120, 68.860
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution39.390 - 1.650
R-factor0.1801
Rwork0.178
R-free0.21650
Structure solution methodFOURIER SYNTHESIS
RMSD bond length0.014
RMSD bond angle1.803
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0103)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]39.39039.3901.670
High resolution limit [Å]1.6307.2901.630
Rmerge0.0770.0321.623
Rmeas0.0840.0342.078
Total number of observations143428
Number of reflections24211352644
<I/σ(I)>15.3555.090.55
Completeness [%]86.596.431.6
Redundancy5.9247.291.739
CC(1/2)0.9990.9990.285
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.5298PEG 8000, HEPES, magnesium chloride

225946

PDB entries from 2024-10-09

PDB statisticsPDBj update infoContact PDBjnumon