6Y1D
Binary complex of 14-3-3 sigma (C38N) with the Estrogen Related Receptor gamma (DBD) phosphopeptide
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PETRA III, DESY BEAMLINE P11 |
| Synchrotron site | PETRA III, DESY |
| Beamline | P11 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-06-22 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 1.0332 |
| Spacegroup name | C 2 2 21 |
| Unit cell lengths | 82.261, 111.949, 62.873 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 45.618 - 1.380 |
| R-factor | 0.1659 |
| Rwork | 0.165 |
| R-free | 0.18730 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3p1n |
| Data reduction software | XDS |
| Data scaling software | Aimless |
| Phasing software | BUSTER |
| Refinement software | PHENIX (1.15.2_3472) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 66.290 | 1.400 |
| High resolution limit [Å] | 1.380 | 1.380 |
| Number of reflections | 59105 | 2440 |
| <I/σ(I)> | 26.2 | 2.6 |
| Completeness [%] | 98.8 | |
| Redundancy | 12.3 | |
| CC(1/2) | 1.000 | 0.790 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.095 M HEPES (pH 7.3), 0.19 M CaCl2, 25% (v/v) PEG 400 and 5% (v/v) glycerol |