Influenza hemagglutinin A/Bangkok/01/1979(H3N2)

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-E
Synchrotron siteAPS
Beamline24-ID-E
Temperature [K]80
Detector technologyPIXEL
Collection date2019-03-26
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.979180
Spacegroup nameC 1 2 1
Unit cell lengths200.660, 186.180, 107.400
Unit cell angles90.00, 110.13, 90.00
Refinement procedure
Resolution48.658 - 3.000
R-factor0.2277
Rwork0.226
R-free0.26220
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6mxu
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.14_3260)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]48.6603.107
High resolution limit [Å]3.0003.000
Rmerge0.1621.101
Rmeas0.187
Rpim0.0920.614
Number of reflections713497168
<I/σ(I)>7.881.2
Completeness [%]96.397.12
Redundancy3.94.1
CC(1/2)0.9930.751
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7291.155% (w/v) PEG 400, 0.5M Sodium citrate, pH7.0

219869