6X79
Prefusion SARS-CoV-2 S ectodomain trimer covalently stabilized in the closed conformation
EM specimen
| Vitrification | Yes |
EM Data Collection
| Microscope | TFS GLACIOS |
| Electron Gun | FIELD EMISSION GUN |
| Accelerating Voltage (kV) | 200 |
| Detector | GATAN K2 SUMMIT (4k x 4k) |
3D Reconstruction
| Method | SINGLE PARTICLE |
| Resolution (Å) | 2.9 |
| Software | cryoSPARC,Leginon |
| Symmetry | C3 |
| CTF correction | PHASE FLIPPING AND AMPLITUDE CORRECTION |