Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6W86

K2P2.1 (TREK-1):ML335 complex, 100 mM K+

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 23-ID-D
Synchrotron siteAPS
Beamline23-ID-D
Temperature [K]100
Detector technologyPIXEL
Collection date2018-06-19
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.03320
Spacegroup nameP 21 21 21
Unit cell lengths67.317, 120.133, 129.431
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution14.940 - 3.299
R-factor0.2526
Rwork0.250
R-free0.28760
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6cq6
RMSD bond length0.011
RMSD bond angle1.160
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareBUSTER (2.10.3 (6-FEB-2020))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]46.6503.560
High resolution limit [Å]3.3003.300
Rmerge0.132
Number of reflections161463319
<I/σ(I)>4.9
Completeness [%]98.7
Redundancy3.7
CC(1/2)0.163
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP827722-25% PEG400, 100mM HEPES pH=8.0, 1mM CdCl2, 200mM KCl

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon