6VTC
p53-specific T cell receptor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-BM |
Synchrotron site | APS |
Beamline | 19-BM |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2019-10-23 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 1.0 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 41.123, 106.369, 112.685 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 31.300 | 1.900 |
High resolution limit [Å] | 1.830 | 1.830 |
Rmerge | 0.081 | 0.328 |
Number of reflections | 44465 | 4396 |
<I/σ(I)> | 30.6 | |
Completeness [%] | 99.7 | |
Redundancy | 7.7 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 6 | 295 | 20% (w/v) PEG 4000, 0.2 M LiSO4, 0.1 M MES |