6VES
Human insulin analog: [GluB10,HisA8,ArgA9]-DOI
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
| Synchrotron site | Australian Synchrotron |
| Beamline | MX2 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2017-08-02 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.95373 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 27.059, 28.992, 46.943 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 24.667 - 1.850 |
| R-factor | 0.1997 |
| Rwork | 0.195 |
| R-free | 0.23920 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | Editted version of human insulin component of PDB entry 4OGA |
| RMSD bond length | 0.004 |
| RMSD bond angle | 0.603 |
| Data reduction software | XDS |
| Data scaling software | Aimless (0.5.21) |
| Phasing software | PHASER |
| Refinement software | PHENIX ((1.13-2998_1692)) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 46.940 | 1.910 |
| High resolution limit [Å] | 1.850 | 1.850 |
| Rmerge | 0.147 | 2.365 |
| Rmeas | 0.162 | 2.588 |
| Rpim | 0.066 | 1.014 |
| Number of reflections | 3456 | 290 |
| <I/σ(I)> | 7.4 | 0.9 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 6 | 6.2 |
| CC(1/2) | 0.995 | 0.405 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 300 | WELL CONDITION: 0.2 M calcium acetate, 0.1 M imidazole (pH 8) + 10% w/v PEG 8000 Protein was provided as a sample comprising 5 mg/ml (IR310.T).Fv83-7 in 10mM HEPES-NaOH (pH7.5) + 0.02% NaN3 plus three mol equivalents of the IR-A alphaCT peptide 704-719 plus 1.8 mol of the analog |