Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6VDE

Full-length M. smegmatis Pol1

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 24-ID-C
Synchrotron siteAPS
Beamline24-ID-C
Temperature [K]100
Detector technologyPIXEL
Collection date2018-02-22
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.97918
Spacegroup nameP 1
Unit cell lengths70.004, 80.940, 117.912
Unit cell angles98.68, 105.13, 109.36
Refinement procedure
Resolution50.366 - 2.713
R-factor0.2368
Rwork0.234
R-free0.30420
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6vdd
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.16_3549)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.5002.750
High resolution limit [Å]2.7002.700
Rpim0.496
Number of reflections601402877
<I/σ(I)>241.7
Completeness [%]98.3
Redundancy4.5
CC(1/2)0.9980.662
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP5.52931 M lithium chloride, 20% PEG6000, 0.1 M MES, 3% dextran sulfate sodium salt

224572

PDB entries from 2024-09-04

PDB statisticsPDBj update infoContact PDBjnumon