6VAR
61 nt human Hepatitis B virus epsilon pre-genomic RNA
Spectrometer
Experimental method: SOLUTION NMR, SOLUTION SCATTERING
Spectrometer ID | Spectrometer maker | Spectrometer model | Spectrometer type | Spectrometer field strength |
1 | Bruker | Ascend | 800 | |
2 | Bruker | Ultrashield Plus | 600 |
Experiment
experiment id | conditions id | solution id | Experiment type |
1 | 1 | 2 | 2D 1H-15N HSQC |
10 | 1 | 2 | 2D HNCCNCH |
11 | 1 | 3 | Filter/Edit NOESY |
2 | 1 | 1 | 2D 1H-13C HSQC aliphatic |
3 | 1 | 1 | 2D 1H-13C HSQC aromatic |
4 | 1 | 2 | 3D 1H-15N NOESY |
5 | 1 | 1 | 3D 1H-13C NOESY aliphatic |
6 | 1 | 1 | 3D 1H-13C NOESY aromatic |
7 | 1 | 2 | 2D 1H-1H NOESY |
8 | 1 | 1 | 2D 1H-1H NOESY |
9 | 1 | 1 | 3D HCN |
NMR Sample
conditions id | NMR sample pH | NMR sample pressure | NMR sample temperature |
1 | 6.4 | 1 | 298 |
Conformers
Conformers Calculated Total Number | 200 |
Conformers Submitted Total Number | 10 |
Refinement Statistics
Experimental method: SOLUTION NMR, SOLUTION SCATTERING
Cell axes | |||
Cell angles | |||
Spacegroup | |||
Resolution limits | - |