Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6V50

Coiled-coil Trimer with Glu:Ser:Lys Triad with K7A mutation

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsENRAF-NONIUS FR591
Temperature [K]100
Detector technologyCCD
Collection date2019-04-02
DetectorAPEX II CCD
Wavelength(s)1.5406
Spacegroup nameH 3
Unit cell lengths39.190, 39.190, 98.610
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution19.946 - 2.285
R-factor0.2028
Rwork0.197
R-free0.26570
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ovs
RMSD bond length0.006
RMSD bond angle0.677
Data reduction softwarePROTEUM PLUS
Data scaling softwarePROTEUM PLUS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.12_2829)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]19.9462.615
High resolution limit [Å]2.2852.285
Rmerge0.1000.354
Rmeas0.1040.104
Rpim0.0290.135
Number of reflections5113258
<I/σ(I)>122.3
Completeness [%]99.9
Redundancy12.6
CC(1/2)0.9990.946
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29840% PEG300, 100 mM HEPES/NaOH, pH 7.5, 200 mM sodium chloride

223166

PDB entries from 2024-07-31