Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6V02

N-terminal 5 domains of CI-MPR

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2017-10-29
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths50.780, 66.220, 124.530
Unit cell angles90.00, 100.53, 90.00
Refinement procedure
Resolution35.910 - 2.460
R-factor0.24356
Rwork0.240
R-free0.30778
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6p8i
RMSD bond length0.006
RMSD bond angle1.215
Data reduction softwareXDS
Data scaling softwareautoPROC
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0258)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]122.4322.760
High resolution limit [Å]2.4602.460
Number of reflections19610981
<I/σ(I)>13.7
Completeness [%]91.158.2
Redundancy53.9
CC(1/2)0.9990.605
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP292.15100 mM HEPES pH 7.0, 30% Jeffamine ED-2003

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon