6UZP

HLA-B*15:01 complexed with a synthetic peptide

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsNSLS-II BEAMLINE 17-ID-2
Synchrotron siteNSLS-II
Beamline17-ID-2
Temperature [K]100
Detector technologyPIXEL
Collection date2018-04-12
DetectorDECTRIS EIGER X 16M
Wavelength(s).92011
Spacegroup nameP 21 21 21
Unit cell lengths50.957, 81.674, 109.611
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution29.693 - 2.080
R-factor0.1867
Rwork0.182
R-free0.24790
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)1xr8
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX (1.13_2998)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]29.7002.150
High resolution limit [Å]2.0802.080
Rmerge0.295
Rmeas0.065
Number of reflections281252663
<I/σ(I)>9.1
Completeness [%]99.6
Redundancy2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP5.62770.2 ammonium acetate, 0.M tri-sodium citrate dihydrate pH5.6, 30% w/v PEG4000

226707

PDB entries from 2024-10-30