6ULP
BRD3-BD2 in complex with the cyclic peptide 3.2_3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-10-18 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 0.953700 |
Spacegroup name | I 4 |
Unit cell lengths | 97.568, 97.568, 77.748 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 38.050 - 2.800 |
R-factor | 0.2121 |
Rwork | 0.210 |
R-free | 0.24770 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 3s92 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.559 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | PHENIX (1.14_3260) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 38.870 | 2.960 |
High resolution limit [Å] | 2.800 | 2.800 |
Number of reflections | 9024 | 1304 |
<I/σ(I)> | 29.9 | |
Completeness [%] | 99.8 | |
Redundancy | 14 | |
CC(1/2) | 1.000 | 0.916 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 8 | 291 | 0.2 M Calcium chloride dihydrate, 0.1 M Tris 8.0, 20 % w/v PEG 6000 |