6TZW
Coiled-coil registry shifts in the F684I mutant of Bicaudal D result in cargo-independent activation of dynein motility
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2019-06-26 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.9791 |
| Spacegroup name | P 31 2 1 |
| Unit cell lengths | 60.045, 60.045, 142.637 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
| Resolution | 19.450 - 2.350 |
| R-factor | 0.2514 |
| Rwork | 0.251 |
| R-free | 0.26000 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 4bl6 |
| RMSD bond length | 0.003 |
| RMSD bond angle | 0.454 |
| Data reduction software | XDS (Implemented in RAPD, a software suite developed by APS) |
| Data scaling software | Aimless (Implemented in RAPD, a software suite developed by APS) |
| Phasing software | PHENIX (1.16-3549) |
| Refinement software | PHENIX (1.16_3549) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 19.650 | 2.434 |
| High resolution limit [Å] | 2.350 | 2.350 |
| Rmerge | 0.044 | 1.621 |
| Rmeas | 0.047 | |
| Rpim | 0.015 | 0.549 |
| Number of reflections | 12955 | 1263 |
| <I/σ(I)> | 28 | 1.26 |
| Completeness [%] | 99.4 | 99.92 |
| Redundancy | 9.7 | 9.6 |
| CC(1/2) | 1.000 | 0.573 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293.15 | 4% PEG 3350, 0.4 M NaSCN, 5% glycerol |