6TUS
human XPG, Apo2 form
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALBA BEAMLINE XALOC |
Synchrotron site | ALBA |
Beamline | XALOC |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-09-01 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9787 |
Spacegroup name | P 42 21 2 |
Unit cell lengths | 134.225, 134.225, 110.810 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.850 - 2.500 |
R-factor | 0.2038 |
Rwork | 0.203 |
R-free | 0.23680 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6tur |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | MOLREP |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 47.850 | 2.589 |
High resolution limit [Å] | 2.500 | 2.500 |
Number of reflections | 35554 | 3887 |
<I/σ(I)> | 14.4 | |
Completeness [%] | 99.8 | |
Redundancy | 7.2 | |
CC(1/2) | 0.999 | 0.439 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 295 | 25% PEG 3350, 100 mM Bis-Tris pH 6.5, 200 mM Amm. Sulfate. |