6TSC

OphMA I407P complex with SAH

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]100
Detector technologyPIXEL
Collection date2019-05-06
DetectorDECTRIS EIGER X 16M
Wavelength(s)0.9795
Spacegroup nameP 32 2 1
Unit cell lengths89.379, 89.379, 157.001
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution52.330 - 2.190
R-factor0.209
Rwork0.208
R-free0.23220
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5n0o
RMSD bond length0.007
RMSD bond angle1.518
Data reduction softwareDIALS
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0257)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]52.3302.230
High resolution limit [Å]2.1902.190
Rmeas0.0582.088
Number of reflections381161877
<I/σ(I)>15.71.1
Completeness [%]100.099.7
Redundancy11.110.9
CC(1/2)1.0000.900
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2890.3-0.4 M KSCN, 0.1 M Bicine pH 8-9, 1.8-2.5 M sodium malonate

225946