6TRL
Human Eg5 motor domain mutant Y82F
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE MASSIF-1 |
Synchrotron site | ESRF |
Beamline | MASSIF-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-07-12 |
Detector | DECTRIS PILATUS3 X 2M |
Wavelength(s) | 0.966000 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 53.075, 77.430, 91.076 |
Unit cell angles | 90.00, 91.81, 90.00 |
Refinement procedure
Resolution | 39.850 - 2.200 |
R-factor | 0.1955 |
Rwork | 0.195 |
R-free | 0.21540 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1ii6 |
Data reduction software | XDS |
Data scaling software | autoPROC |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.480 | 2.270 |
High resolution limit [Å] | 2.200 | 2.200 |
Rmerge | 0.034 | 0.446 |
Rmeas | 0.044 | 0.583 |
Rpim | 0.028 | 0.371 |
Number of reflections | 56409 | 1934 |
<I/σ(I)> | 12.8 | 2 |
Completeness [%] | 88.0 | 59.8 |
Redundancy | 2.2 | 2.1 |
CC(1/2) | 0.999 | 0.787 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.6 | 277.15 | PEG3350, NaNO3, MES |