6TME
Monomeric LRX8 in complex with RALF4.
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 80 |
Detector technology | PIXEL |
Collection date | 2019-08-16 |
Detector | DECTRIS PILATUS 2M-F |
Wavelength(s) | 1.000036 |
Spacegroup name | P 1 |
Unit cell lengths | 51.806, 65.542, 83.700 |
Unit cell angles | 72.12, 87.62, 68.36 |
Refinement procedure
Resolution | 48.000 - 2.330 |
R-factor | 0.1745 |
Rwork | 0.172 |
R-free | 0.22880 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6qxp |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 48.000 | 48.000 | 2.410 |
High resolution limit [Å] | 2.330 | 9.010 | 2.330 |
Rmerge | 0.136 | 0.058 | 0.908 |
Rmeas | 0.161 | 0.068 | 1.073 |
Rpim | 0.086 | 0.036 | 0.565 |
Total number of observations | 142274 | 2502 | 12840 |
Number of reflections | 40550 | 688 | 3700 |
<I/σ(I)> | 6.6 | 19.6 | 1.4 |
Completeness [%] | 97.2 | 95 | 90.4 |
Redundancy | 3.5 | 3.6 | 3.5 |
CC(1/2) | 0.991 | 0.993 | 0.550 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 292 | 0.3 M Ammonium sulfate 20 % w/v PEG 4000 |