VSV G_440

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE BM30A
Synchrotron siteESRF
BeamlineBM30A
Temperature [K]93
Detector technologyPIXEL
Collection date2018-10-15
DetectorDECTRIS PILATUS3 2M
Wavelength(s)0.987
Spacegroup nameP 6 2 2
Unit cell lengths120.950, 120.950, 200.320
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution44.820 - 2.070
R-factor0.2083
Rwork0.207
R-free0.24170
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5i2s
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwareMOLREP
Refinement softwarePHENIX (1.17_3644)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.8202.350
High resolution limit [Å]2.0702.070
Number of reflections528706568
<I/σ(I)>8.27
Completeness [%]99.5
Redundancy6.8
CC(1/2)0.9000.396
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.52938% PEG8000, 0.15M calcium acetate, 0.15M HEPES pH7.5