Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04-1 |
| Synchrotron site | Diamond |
| Beamline | I04-1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2017-03-13 |
| Detector | DECTRIS PILATUS 2M |
| Wavelength(s) | 0.9282 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 100.667, 101.210, 170.826 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 85.559 - 1.250 |
| Rwork | 0.114 |
| R-free | 0.13610 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 6en9 |
| RMSD bond length | 0.019 |
| RMSD bond angle | 2.136 |
| Data reduction software | DIALS |
| Data scaling software | Aimless |
| Phasing software | PHASER |
| Refinement software | REFMAC (5.8.0257) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 86.800 | 1.270 |
| High resolution limit [Å] | 1.250 | 1.250 |
| Rmerge | 0.107 | 1.640 |
| Rmeas | 0.122 | 1.920 |
| Rpim | 0.059 | 0.970 |
| Number of reflections | 477343 | 21628 |
| <I/σ(I)> | 9 | 1.1 |
| Completeness [%] | 99.4 | 91.5 |
| Redundancy | 8.1 | 7.2 |
| CC(1/2) | 0.998 | 0.553 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION | 6.5 | 296 | 100 mM Bis Tris pH 6.5, 200 mM MgCl2, 18-22% PEG 3350 |