Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6SRO

X-ray pump X-ray probe on thaumatin nanocrystals: 76 fs time delay

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeFREE ELECTRON LASER
Source detailsSLAC LCLS BEAMLINE CXI
Synchrotron siteSLAC LCLS
BeamlineCXI
Temperature [K]293
Detector technologyPIXEL
Collection date2015-02-15
DetectorCS-PAD CXI-1
Wavelength(s)1.75
Spacegroup nameP 41 21 2
Unit cell lengths57.849, 57.849, 150.328
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution23.000 - 2.300
R-factor0.1472
Rwork0.145
R-free0.17690
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5fgt
RMSD bond length0.013
RMSD bond angle1.859
Data reduction softwareCrystFEL
Data scaling softwareXSCALE
Phasing softwareREFMAC
Refinement softwareREFMAC (5.8.0232)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]23.0002.360
High resolution limit [Å]2.3202.320
Number of reflections11104850
<I/σ(I)>7.64.2
Completeness [%]100.0
Redundancy1
CC(1/2)0.9790.965
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE72930.8 M NA, K TARTRATE, 0.1 M NA HEPES PH 7.0

218853