Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6SQW

Mouse dCTPase in complex with 5-Me-dCMP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID29
Synchrotron siteESRF
BeamlineID29
Temperature [K]100
Detector technologyPIXEL
Collection date2015-11-14
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.07
Spacegroup nameP 41 21 2
Unit cell lengths58.516, 58.516, 140.905
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution54.040 - 1.800
R-factor0.193
Rwork0.192
R-free0.21490
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.014
RMSD bond angle1.596
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]54.5001.900
High resolution limit [Å]1.8001.800
Rmerge0.1301.360
Number of reflections2353332921
<I/σ(I)>12.21.7
Completeness [%]100.0
Redundancy13.9
CC(1/2)0.9900.500
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2910.1 M Tris pH 8.75, 2.4 M ammonium sulfate

224004

PDB entries from 2024-08-21

PDB statisticsPDBj update infoContact PDBjnumon