6SCU

THERMOLYSIN IN COMPLEX WITH FRAGMENT J88

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.1
Synchrotron siteBESSY
Beamline14.1
Temperature [K]100
Detector technologyPIXEL
Collection date2016-03-11
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9184
Spacegroup nameP 61 2 2
Unit cell lengths92.307, 92.307, 129.622
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution46.150 - 1.420
R-factor0.1333
Rwork0.132
R-free0.16200
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)NONE
RMSD bond length0.006
RMSD bond angle0.882
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwarePHENIX (1.16_3549)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.510
High resolution limit [Å]1.4201.420
Number of reflections619539812
<I/σ(I)>18.94.4
Completeness [%]100.099.9
Redundancy8.3
CC(1/2)0.9990.945
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5291.1550 MM TRIS/HCL, 1.9 M CSCL, 50% DMSO

222624