6S2M
Perdeuterated human myelin protein P2 at 0.72-A resolution
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | PETRA III, DESY BEAMLINE P11 |
Synchrotron site | PETRA III, DESY |
Beamline | P11 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2013-09-27 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.7443 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 112.180, 36.210, 31.110 |
Unit cell angles | 90.00, 97.03, 90.00 |
Refinement procedure
Resolution | 27.834 - 0.720 |
R-factor | 0.1043 |
Rwork | 0.104 |
R-free | 0.11070 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4bvm |
RMSD bond length | 0.020 |
RMSD bond angle | 1.763 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.14_3260: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 0.740 |
High resolution limit [Å] | 0.720 | 0.720 |
Rmeas | 0.039 | 1.435 |
Number of reflections | 162608 | 6984 |
<I/σ(I)> | 15.8 | 0.9 |
Completeness [%] | 91.0 | 53.2 |
Redundancy | 4.7 | 3.3 |
CC(1/2) | 0.999 | 0.405 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 4.25 | 281 | 24% PEG6000, 0.1 M sodium citrate, pH 5 |