Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6R5J

New MAX Effector from Magnaporthe oryzae

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE MASSIF-1
Synchrotron siteESRF
BeamlineMASSIF-1
Temperature [K]100
Detector technologyPIXEL
Collection date2018-04-18
DetectorDECTRIS PILATUS3 2M
Wavelength(s)1
Spacegroup nameC 1 2 1
Unit cell lengths73.341, 24.760, 68.613
Unit cell angles90.00, 100.88, 90.00
Refinement procedure
Resolution34.589 - 1.380
R-factor0.1442
Rwork0.143
R-free0.17050
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)NMR model
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.15_3448)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]34.5901.430
High resolution limit [Å]1.3801.380
Number of reflections591022877
<I/σ(I)>14
Completeness [%]93.7
Redundancy2.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2980,1M Hepes pH 7.5 1.6M Ammonium Sulfate 1,6M PEG 1000

224004

PDB entries from 2024-08-21

PDB statisticsPDBj update infoContact PDBjnumon